RFC 2544 Tabs
Ethernet and Fibre Channel Application 301
Throughput
Maximum Rate:
TX-to-RX/P1-to-P2/P2-to-P1/Local to Remote/Remote to Local: Select
the maximum rate for the test. The default setting is 100% for
10/100/1000 Mbps and 10 Gig-E LAN, and 92.8571428571429% for
10 Gig-E WAN. P1-to-P2/P2-to-P1 is only available with RTU-310.
Choices are:
Select the rate’s unit. Choices are %, and Mbps/Gbps. The default unit
is %.
Minimum Test Time: Indicates the minimum time the test requires to
run at best condition. The minimum test time is calculated and
updated once the test is started.
Interface Unit
Rate
from to
10 Mbps % 0.005 100.0
Mbps 0.0005 10.0
100 Mbps % 0.005 100.0
Mbps 0.005 100.0
1000 Mbps % 0.005 100.0
Mbps 0.05 1000.0
10 Gig-E LAN % 0.005 100.0
Gbps 0.0005 10.0
10 Gig-E WAN % 0.005 92.8571428571429
Gbps 0.0005 9.2857142857142865