Page view 474
Specifications
Ethernet Test Module 463
Specifications for RTU-310G
Synchronization Interfaces
DS1/E1 external input clock interface
Eye safety CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1
Connector Duplex
LC
Duplex
LC
Duplex
LC
Duplex
LC
Duplex LC Duplex LC
Transceiver type XFP XFP XFP XFP XFP XFP
Parameter DS1 E1
Rx level sensitivity
(short haul only)
For 772 kHz: TERM: 6
dB (cable loss only)
For 1024 kHz: TERM: 6
dB (cable loss only)
Reception bit rate 1.544 Mbit/s ± 50 ppm 2.048 Mbit/s ± 50 ppm
Input jitter tolerance AT&T PUB 62411,
GR-499 section 7.3
G.823 section 7.2
Line coding AMI and B8ZS HDB3 and AMI
Input impedance
(resistive termination)
100 ohms ± 5%,
balanced
120 ohms ± 5%,
balanced
Connector type BANTAM BANTAM
10GBASE-S
W
10GBASE-S
R
10GBASE-LW 10GBASE-LR 10GBASE-EW 10GBASE-ER