Creating and Starting a Test Case
90 FTB-8500 Series and FTB-8120NGE/8130NGE
Ethernet RFC 2544 Test Case
To create an RFC 2544 test case:
1. Test configuration:
1a. Select Ethernet 10/100/1000 as the
Interface Type. Interface Type is not
available with RTU-310G.
1b. For RTU-310: Select the Topology test
type: Single Port or Dual Ports.
1c. Select RFC 2544 as the Application
Type.
1d. Select the desired RFC 2544 sub test(s).
All RFC 2544 sub tests are selected by
default.
Throughput: Gives the maximum throughput of the device under
test for which there is no frame loss. Refer to Throughput on
page 299 for more information.
Back-to-Back: Gives the maximum number of frames that can be
sent at maximum throughput. Refer to Back-to-Back on page 304
for more information.
Frame Loss: Gives the percentage of frames that are lost. Refer to
Frame Loss on page 308 for more information.
Latency: Gives the time required for the sent frame to go through
the device under test. Refer to Latency on page 312 for more
information.
1e. Leave the Dual Test Set check box cleared. For Dual Test Set test
case, refer to Ethernet EtherSAM (Y.1564) and RFC 2544 Dual Test
Set Test Cases on page 80.
1f. Click Next.